1. General
1.1 Electric ratings: 230V, AC50/60Hz;
1.2 Utilization category: AC-14;
1.3 Rated conventional heating current lth: 16A;
1.4 Rated operational current Ie: 6A;
1.5 Rated insulation voltage Ui: 500V;
1.6 Protection grade: IP20;
1.7 Standard: IEC/EN 60947-5-1;
2. Operating conditions
2.1 Ambient temperature: -5℃~+40℃, average temperature in 24 hours not exceed +35℃;
2.2 Altitude: ≤ 2000m;
2.3 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20℃. Special measures should be taken to occurrence of dews;
2.4 Mounting category: Ⅱ, Ⅲ;
2.5 Pollution grade: Ⅱ; 2.6 Mounting mode: TH35-7.5 standard rail, inclination between mounting and vertical plane not exceed 5°.
3. Technical data
3.1 Life (operations): a. Electric life : 100,000 b. Mechanical life : 250,000
3.2 Assembly of contact: 1NC+2NO, 2NC+1NO, 3NO, 2NC+2NO(Not available for illuminated type)
3.3 Technical data of signal lamp a. Rated operational voltage: AC/DC6.3V, AC/DC12V, AC/DC24V, AC/DC110V, AC/DC230V b. Rated operational current: ≤20mA
3.4 Life: LED≥30000h
NP9 Pushbutton
1. General
1.1 Electric ratings: 230V, AC50/60Hz;
1.2 Utilization category: AC-14;
1.3 Rated conventional heating current lth: 16A;
1.4 Rated operational current Ie: 6A;
1.5 Rated insulation voltage Ui: 500V;
1.6 Protection grade: IP20;
1.7 Standard: IEC/EN 60947-5-1;
2. Operating conditions
2.1 Ambient temperature: -5℃~+40℃, average temperature in 24 hours not exceed +35℃;
2.2 Altitude: ≤ 2000m;
2.3 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20℃. Special measures should be taken to occurrence of dews;
2.4 Mounting category: Ⅱ, Ⅲ;
2.5 Pollution grade: Ⅱ; 2.6 Mounting mode: TH35-7.5 standard rail, inclination between mounting and vertical plane not exceed 5°.
3. Technical data
3.1 Life (operations): a. Electric life : 100,000 b. Mechanical life : 250,000
3.2 Assembly of contact: 1NC+2NO, 2NC+1NO, 3NO, 2NC+2NO(Not available for illuminated type)
3.3 Technical data of signal lamp a. Rated operational voltage: AC/DC6.3V, AC/DC12V, AC/DC24V, AC/DC110V, AC/DC230V b. Rated operational current: ≤20mA
3.4 Life: LED≥30000h