NL210 Residual Current Operated Circuit Breaker without Over-current Protection

1.1 Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.

1.2 Selection

Detectable wave form

Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

      Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts; 

300mA - protection against indirect contacts, as well as fire hazard. 

      Tripping time

Instantaneous

It ensures instantaneous tripping (without time-delay).

1.3 Approvals and certificates CE, KEMA

1.4 Add-on devices

AX-5 auxiliary contacts

TC-1 terminal cover


1.1 Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.

1.2 Selection

Detectable wave form

Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

      Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts; 

300mA - protection against indirect contacts, as well as fire hazard. 

      Tripping time

Instantaneous

It ensures instantaneous tripping (without time-delay).

1.3 Approvals and certificates CE, KEMA

1.4 Add-on devices

AX-5 auxiliary contacts

TC-1 terminal cover


NL210 Residual Current Operated Circuit Breaker without over-current protection Sample.pdf70.16 KB
NL210(3P+N)_CE.pdf1.06 MB
NL210 (1P+N)_CE.PDF2.24 MB
NL210_2D(V1).dwg993.72 KB
NL210_3D(V1).igs21.79 MB
  • Produtos
  • Soluções
    • Fotovoltaico - GD
    • Fotovoltaico - Off-grid
    • Iluminação Pública - Fotovoltaica
    • Bomba de Água - Solar
  • Serviços
    • Atendimento ao Cliente
    • Perguntas
    • Centro de Downloads
  • Sobre Nós
    • Empresa
    • Novidades
    • Contato
    • Integridade & Compliance
  • Carreiras
Sunlight