NB1-63 Miniature Circuit Breaker

1.1 Function

protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.

NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.

1.2 Selection

Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage.

Tripping curves:

B curve (3-5In) 

protection for people and big length cables in TN and IT  systems. 

      C curve (5-10In)

protection for resistive and inductive loads with low inrushcurrent.

      D curve(10-14In)

protection for circuits which supply loads with high inrush current at the circuit closing 

(LV/LV transformers, breakdown lamps).

1.3 Approvals and certificates

Detailed information, please refer to Certificates Table on the last page.


1.1 Function

protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.

NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.

1.2 Selection

Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage.

Tripping curves:

B curve (3-5In) 

protection for people and big length cables in TN and IT  systems. 

      C curve (5-10In)

protection for resistive and inductive loads with low inrushcurrent.

      D curve(10-14In)

protection for circuits which supply loads with high inrush current at the circuit closing 

(LV/LV transformers, breakdown lamps).

1.3 Approvals and certificates

Detailed information, please refer to Certificates Table on the last page.


NB1-63 catalog.pdf916.90 KB
NB1-63 IEC60947.pdf286.51 KB
NB1-63 UL1077.pdf219.67 KB
NB1-63.pdf882.77 KB
NB1-63 63H 63DC REACH 202408.pdf356.50 KB
NB1-63 EAC 202206.pdf614.94 KB
NB1-63 TüV 202305.pdf1.86 MB
NB1-63 SIRIM 202402.pdf1.27 MB
NB1-63 SII 240101.pdf784.09 KB
NB1-63 CB 202311.pdf626.92 KB
NB1-63 INMETRO 202211.pdf1.05 MB
NB1-63 SLS 230508.pdf3.16 MB
NB1-63 4P C16 KC 202304.pdf903.49 KB
NB1-63 IMQ 202206.pdf548.57 KB
NB1-63 DNV 202312.pdf192.61 KB
NB1-63 SEMKO 202311.pdf817.40 KB
NB1-63 UKCA 202301.pdf210.32 KB
NB1-63 UA TR 202403.pdf4.12 MB
NB1-63 InA_ LOA 202404.pdf45.54 KB
NB1-63 Carbon Footprint 202311.pdf531.76 KB
NB1-63,NB1-63H证书(UL)202104.pdf209.71 KB
NB1-63_VDE.PDF672.10 KB
NB1-63_CE.pdf88.17 KB
NB1-63_CE (60947-2).pdf88.17 KB
NB1-63-2P_3D(V1).igs27.04 MB
NB1-63-2P_2D(V1).dwg277.19 KB
NB1-63-4P_2D(V1).dwg297.57 KB
NB1-63-1P_3D(V1).igs27.38 MB
NB1-63-1P_2D(V1).dwg1.06 MB
NB1-63-4P_3D(V1).igs51.91 MB
  • Produtos
  • Soluções
    • Fotovoltaico - GD
    • Fotovoltaico - Off-grid
    • Iluminação Pública - Fotovoltaica
    • Bomba de Água - Solar
  • Serviços
    • Atendimento ao Cliente
    • Perguntas
    • Centro de Downloads
  • Sobre Nós
    • Empresa
    • Novidades
    • Contato
    • Integridade & Compliance
  • Carreiras
Sunlight